Power Requirements - Frymaster FQE60U FilterQuick easyTouch Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

2.2

Power Requirements

The optional three phase supply plug for 208v and 240v delta configuration fryers are rated at 60 amps,
250 VAC and is NEMA configuration 15-60P.
FQE60U 14kW
FQE60U 14kW
FQE60U 14kW
FQE60U 14kW
FQE60U 14kW
FQE60U 14kW
FQE60U 17kW
FQE60U 17kW
FQE60U 17kW
FQE60U 17kW
FQE60U 17kW
FQE60U 17kW
FQE60U 22kW
FQE60U 22kW
FQE60U 22kW
FQE60U 22kW
FQE60U 22kW
FQE60U 22kW
FQE60U 14kW
FQE60U 14kW
FQE60U 14kW
If this appliance is permanently connected to fixed wiring, it must be connected by means of
copper wires having a temperature rating of not less than 167°F (75°C).
This appliance must be connected to a power supply having the same voltage and phase as
specified on the rating plate located on the inside of the appliance door.
All wiring connections for this appliance must be made in accordance with the wiring diagram(s)
furnished with the appliance.
appliance door when installing or servicing this equipment.
Three (3) Phase Requirements
MODEL
VOLTAGE
208
240
480
220/380
240/415
230/400
208
240
480
220/380
240/415
230/400
208
240
480
220/380
240/415
230/400
Single Phase Requirements
MODEL
VOLTAGE
208
240
480
Refer to the wiring diagram(s) affixed to the inside of the
MINIMUM WIRE
WIRE
SIZE
SERVICE
AWG
(mm)
3
6
(4.11)
3
6
(4.11)
3
8
(2.59)
4
6
(4.11)
4
6
(4.11)
4
6
(4.11)
3
6
(4.11)
3
6
(4.11)
3
6
(4.11)
4
6
(4.11)
4
6
(4.11)
4
6
(4.11)
3
4
(5.19)
3
4
(5.19)
3
6
(4.11)
4
6
(4.11)
4
6
(4.11)
4
6
(4.11)
MINIMUM WIRE
WIRE
SIZE
SERVICE
AWG
(mm)
2
3
(5.83)
2
4
(5.19)
2
8
(3.26)
NOTICE
DANGER
DANGER
2-3
AMPS
(per leg)
39
34
17
21
20
21
48
41
21
26
24
25
61
53
27
34
31
32
AMPS
(per leg)
68
59
30