    NON-CE & PARTS LIST INCLUDED Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service Hotline 1-800-551-8633 MARCH 2007 *8195712*...
  • Page 2 Please read all sections of this manual and retain for future reference. This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster and Dean Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty.
  • Page 3 If a flexible gas line is used, an additional restraining cable must be connected at all The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be posted in a prominent location.
  • Page 4: Table Of Contents

    KSCF18G Cool Zone Gas Fryers INSTALLATION & OPERATION MANUAL INTRODUCTION IMPORTANT INFORMATION INSTALLATION INSTRUCTIONS DAILY OPERATION FILTRATION PREVENTATIVE MAINTENANCE TROUBLESHOOTING PARTS LIST: DOUBLE AND TRIPLE UNITS (218/318) PARTS LIST: SINGLE UNITS (118) TABLE OF CONTENTS Page #...
  • Page 5: Introduction

    CHAPTER 1: INTRODUCTION 1.1 Applicability and Validity The KSCF18G Cool Zone Series gas model family has been approved by the European Union (EU) for sale and installation in the following EU countries: AT, BE, KE, KD, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE.
  • Page 6: Service Information

    KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.4 Service Information Call the Frymaster Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center ( ). To assist you more efficiently, always provide the service FASC technician with the model number, gas type, serial number, and the nature of the problem.
  • Page 7 All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory.
  • Page 8: Important Information

    C. Frying systems with built-in filtration: Take off the filter support brace and remove the filter pan from the cabinet. D. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to initial fryer operation will make it very difficult to remove later.
  • Page 9: Principles Of Operation

    A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service. 2. The Frymaster KSCF18G gas fryers require 120 volts (AC) 60-cycle electrical service for non-CE installation (U.S./Canada/Mexico) and 230 volts (AC) 50-cycle electrical service for CE/International installations.
  • Page 10 B. Clearances: The fryer area must be free of all combustibles. This unit is design-certified for the following installations: Commercial installation only; not for household use.
  • Page 11: Air Supply And Ventilation

    4. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the gas combustion of the fryer.
  • Page 12: Conversion Of Units

    2. With the fryer level in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduits/connections or the gas supply line.
  • Page 13 CHAPTER 2: IMPORTANT INFORMATION 2.9 Restraining the Fryer (cont.) NOTE: If you need to relocate a fryer installed with legs, remove all weight from each leg before moving. If a leg is damaged, contact your service agent for immediate repair or replacement.
  • Page 14: Installation Instructions

    Failure to use qualified, licensed, and/or authorized installation or service personnel to install, convert to another gas type, or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.
  • Page 15: Leveling The Fryer

    For caster retrofit, the unit must be at room temperature and drained of shortening 3.3 Leveling the Fryer A. Place a level across the top of the fryer and level the unit front-to-back. If the fryer is uneven side-to-side, a platform or other surface adjustment is needed; there is no side-to-side level adjustments on a fryer equipped with caster/leg combinations (If a fryer is equipped with legs only, side to side level adjustments can be made.
  • Page 16 • Rigid Casters (Only) 1. Install rigid casters on the fryer rear channel only. Legs must be installed on the front channel. 2. There are no level-adjustments for the rigid casters.
  • Page 17: Gas Connections

    37 and 50 GB Great Britain The gas supply (service) line must be the same size or greater than the fryer inlet line. KSCF18G gas fryers are equipped with a ¾-inch (22-mm) male inlet. The gas supply line must be sized to accommodate all gas-fired equipment connected to that gas supply.
  • Page 18 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.4 Gas Connections (cont.) Supply Line Specifications The gas supply lines must be sized as indicated in the chart below, based on the total number of fryers connected to the main gas supply.
  • Page 19 Regulating Gas Pressure The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the gas supply system, especially if the test pressures are in excess of ½...
  • Page 20 3. The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.
  • Page 21: Gas Inputs

    1. Gas inputs and pressures; 2. Voltage and polarities of electrical power supplies. B. Frymaster gas fryers are manufactured to use the type of gas and pressure specified on the rating plate. When changing gas, adaptation must be performed by qualified personnel.
  • Page 22 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS C. Adjustments for different gases are as follows: ORIFICE SIZE GAS TYPE (# / MM) #42 / 2,40 #42 / 2,40 #53 / 1,51 NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
  • Page 23 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.7 Gas Conversion: Procedures (cont.) When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50 mbar), the following procedures apply: • Check pilot adjustment and adjust as necessary.
  • Page 24 3.9 Safety Switches A. Fryer with KFC-1 Computer This fryer/filter system is equipped with a drain valve safety switch and a frypot float-switch on each of the two-batteried fryers. Drain-valve safety switches de-energize the control circuit during the filter process, thus providing an additional safety feature. Always leave the computer ON when filtering.
  • Page 25 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.9 Safety Switches (cont.) B. Other Fryer/Filter Switches Drain Valve Microswitch: The computer will display DRAIN OPEN when the drain valve is opened. The computer will lockout, preventing any cooking operation until EXIT/COOL FILTER is pressed.
  • Page 26 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.9 Safety Switches (cont.) C. Filtering: Drain Valve and Oil Return Handles Drain Valve Handle: RED HANDLE. Push the red handle (located in the fryer cabinet) to the right to open the drain valve when filtering.
  • Page 27 The KSCF18G frypot shortening capacity is approximately 40.5 kg (90 lb). Ensure fryer power switches are OFF. 3. Cooking Oil: Fill the fryer to the bottom OIL LEVEL line scribed into the back of the frypot. Replace the basket support screen.
  • Page 28 CHAPTER 3: INSTALLATION INSTRUCTIONS 3.11 Final Preparation (cont.) NOTE: If the float switch is blocked in "down position" with solid shortening, the fryer will not heat. Always ensure that the float switch is in the "up" position when packing solid shortening into frypot.
  • Page 29: Daily Operation

    4.2 Start-Up Procedures 1. If the fryer is empty, pour enough oil into the frypot to fill it to the bottom OIL LEVEL line scribed on the rear wall. If solid shortening is used, melt the shortening following procedures in Section 3.11, Final Preparation.
  • Page 30 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION 4.2 Start-Up Procedures (cont.) g. If the pilot does not stay lit, depress the white pilot light button and re-light the pilot (repeat Step f above). Hold the button in longer before releasing. Trapped air may necessitate re-lighting the pilot several times until gas flow is constant.
  • Page 31 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the end of frying operations each day. Some food particles can spontaneously combust if left soaking in certain shortening material.
  • Page 32: Filtration

    To conduct filter operations with the KFC-1 Cooking Computer installed on the fryer, ALWAYS leave the computer ON when filtering. The computer must sense the drain valves opening and closing in order to allow fryer operation.
  • Page 33 KSCF18G COOL ZONE SERIES GAS FRYERS 5.2 Filter Preparation (cont.) 1. Put on protective gear/gloves. Pull the filter pan out of the filter cabinet. Remove cover. 2. Remove crumb screen. If crumbs are present in the crumb screen, empty the screen into a fireproof container.
  • Page 34 KSCF18G COOL ZONE SERIES GAS FRYERS 5.2 Filter Preparation (cont.) 5. Remove the filter screen from the bottom of the pan. 6. Thoroughly clean the pan and all pan components as described for the crumb screen (Step 2). 7. Inspect the pickup tube and ensure vent hole is open and free of shortening/debris.
  • Page 35 KSCF18G COOL ZONE SERIES GAS FRYERS 5.2 Filter Preparation (cont.) 8. Replace filter screen and drape one sheet of filter paper across the filter pan. The filter screen must be installed prior to filter paper placement or the filter won’t operate correctly.
  • Page 36 KSCF18G COOL ZONE SERIES GAS FRYERS 5.3 Filter Operations NOTE: When left and right are indicated, refer to the operator’s left and right. Draining and filtering of cooking oil or shortening must be accomplished with care to avoid a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C).
  • Page 37 KSCF18G COOL ZONE SERIES GAS FRYERS 5.3 Filter Operations (cont.) 2. Remove the support grid from the frypot using the clean-out rod. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining. 3. Open the fryer drain valve by pushing the red handle (under the frypot to be filtered) to the right until it is completely open.
  • Page 38 KSCF18G COOL ZONE SERIES GAS FRYERS 5.3 Filter Operations (cont.) 4. Use the L-shaped brush to scrub the frypot, and to assist in sediment removal. Brush the frypot sides and between the tubes to remove debris. Use the clean-out rod to clear the drain if necessary.
  • Page 39 KSCF18G COOL ZONE SERIES GAS FRYERS 5.3 Filter Operations (cont.) 8. Turn off the filter by turning the oil return handle to the CLOSED position and pushing the oil return handle in until it stops. This closes the oil return valve under the filtered frypot and stops the filter pump motor.
  • Page 40: Preventative Maintenance

    Never attempt to clean the fryer during the cooking process or when the frypot is filled with hot oil. If water comes in contact with oil heated to cooking temperature, it will cause spattering of the oil, which can result in severe burns to nearby personnel.
  • Page 41 This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster and Dean recommend that a Factory Authorized Service Technician should inspect this appliance at least annually, as follows: • Inspect the cabinet inside-and-out, front-and-rear for excessive oil build-up.
  • Page 42: Stainless Steel

    6.4 Stainless Steel All stainless steel fryer outer parts should be wiped regularly with hot, soapy water during the day and with a liquid cleaner designed for this material at the end of each day.
  • Page 43: Troubleshooting

    Although this chapter covers the most common problems reported, you may encounter problems, which are not addressed. In such instances, the Frymaster/Dean Technical Service staff will make every effort to help you identify and resolve the problem.
  • Page 44 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.2 Fryer Troubleshooting Computer fails to turn ON 7.2.1 when ON/OFF button is pressed. Fuses are located inside the cabinet, under the component box. Computer is ON, but the 7.2.2 gas valves fail to energize.
  • Page 45 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.2 Fryer Troubleshooting (cont.) Actual frypot temperature 7.2.3 differs from (cont.) setpoint temperature. Temperature High-Limit Probe Probe Temperature Probe Probe Bracket Burner Tube 5. The thermometer temperature should be within ±10°F (±5°C) of the computer display temperature.
  • Page 46 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.2 Fryer Troubleshooting (cont.) DRAIN OPEN message 7.2.4 remains after closing drain valve. Pump motor won’t start or 7.2.5 stops during filtering. 1. Computer was turned OFF while draining frypot. 2. Close drain valve. Turn computer OFF and ON again.
  • Page 47 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING Fryer Troubleshooting (cont.) 7.2.6 Main burner malfunctions. A. Main burner will not ignite; no gas is present at main burner. Check that float switch is not stuck in the "down" position.
  • Page 48 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.3 Filtration System Troubleshooting Pump won't start. Pump stops during filtering process. Motor is hot. Pump stops and motor is cool. Pump starts and abruptly stops. Pumping is erratic. Oil not being returned to frypot.
  • Page 49 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4 Wiring Diagrams 7.4.1 Normally Open Float Switch (Right)
  • Page 50 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.2 Normally Open Float Switch (Left)
  • Page 51 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.3 CE, Normally Open Float Switch (Right)
  • Page 52 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.4 CE, Normally Open Float Switch (Left) 7-10...
  • Page 53 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.5 Fast Ready 218G (KSCF218GP00001) 7-11...
  • Page 54 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.6 Fast Ready 218G (KSCF218GP00001, KSCF218GN00007) 7-12...
  • Page 55 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.7 Thermatron, 230V CE 7-13...
  • Page 56 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.8 Constant Pilot, Fast Ready 218G 7-14...
  • Page 57 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.9 Constant Pilot with KFC-1, 218G 7-15...
  • Page 58 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.10 Oil Return, 218G/318G (with Vent Solenoids) 7-16...
  • Page 59 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.11 CE, Single 7-17...
  • Page 60 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.12 Oil Return, Single 7-18...
  • Page 61 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7.4.12 Oil Return, Single 7-19...
  • Page 62 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) For parts and/or components not listed, contact the Frymaster Service Hotline at 1-800-551-8633 or 1-318-865-1711 for additional service and parts information. 8.1 Cabinetry and Related Components...
  • Page 63 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.1 Cabinetry and Related Components (cont.) ITEM PART # 201-9081 Side, Cold Rolled Steel Cabinet, Left 202-9081 Side, Cold Rolled Steel Cabinet, Right 211-9606 Side, Stainless Steel Cabinet, Left...
  • Page 64 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.2 Accessories ITEM PART # 803-0306 Twin Fry Basket 211-8178 Joiner Strip (to mount unit to the left of a 2424G) 212-8178 Joiner Strip (to mount unit to the right of a 2424G)
  • Page 65 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.3 Component Box, Computers, and Related Components Speaker mounts directly into component box.
  • Page 66 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.3 Component Box, Computers, and Related Components (cont.) ITEM PART # 824-1465 Component Box 807-4114 Relay, DPDT, 24VAC 106-1414 Relay Socket 807-3613 Relay Spring 200-1337...
  • Page 67 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.4 Drain Valve, Oil Return, and Related Components Oil Return Valves, Fittings, and Components Drain Valve Assembly (106-4672) Included with Item 8 (106-4717) 3-Way Valve Assembly...
  • Page 68 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.4 Drain Valve, Oil Return, and Related Components (cont.) ITEM PART # 106-4672 Drain Valve and Microswitch Components 106-1401 210-9374 200-9345 823-5181 816-0547 807-2104 826-1366...
  • Page 69 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.5 Drain System ITEM PART # 1.5" Drain System (previous style) 823-3358 823-3357 823-3221 823-3222 210-2311 813-0687 823-3440 3" Drain System (current style) 823-5180 823-4950...
  • Page 70 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.6 Filter Pan and Related Components Completely Assembled Filtration Unit...
  • Page 71 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.6 Filter Pan and Related Components (cont.) ITEM PART # Filter Pan Assembly 823-5214 106-7330 803-0299 810-2911 823-4832 106-4693 810-0180 810-2805 809-0823 813-0568 823-4839 Other Components...
  • Page 72 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.7 Frypot and Related Components ITEM PART # 823-4884 Frypot, Stainless Steel, with 1½" Drain 803-0149 Grid, Frypot 210-8387 Diffuser Assembly 200-1615 Support, Manifold 810-2151...
  • Page 73 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.8 Gas Valves, Pilot Assemblies, and Related Components CE Gas Valve(s) Non-CE Gas Valve(s) 8-12...
  • Page 74 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.8 Gas Valves, Pilot Assemblies, and Related Components (cont.) ITEM PART # 807-3552 Gas Valve, Natural and Manufactured Gas, 24V (Non-CE) 807-3628 Gas Valve, LP, 24V (Non-CE)
  • Page 75 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.9 Over-the-Top Oil Return and Related Components 8-14...
  • Page 76 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 8: PARTS LIST: DOUBLE & TRIPLE UNITS (218G/318G) 8.9 Over-the-Top Oil Return and Related Components (cont.) ITEM PART # 106-2983 Oil Return Assembly 823-3344 813-0826 813-0780 813-0777 813-0742 813-0676 813-0625 813-0265 813-0173 813-0165...
  • Page 77 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) For parts and/or components not listed, contact the Frymaster Service Hotline at 1-800-551-8633 or 1-318-865-1711 for additional service and parts information. 9.1 Cabinetry and Related Components...
  • Page 78 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.1 Cabinetry and Related Components (cont.) ITEM PART # 201-1299 Side, Painted Panel, Left 202-1299 Side, Painted Panel, Right 211-4570 Side, Stainless Steel, Left 212-4570 Side, Stainless Steel, Right...
  • Page 79 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.2 Accessories ITEM PART # 803-0306 Twin Fry Basket 211-8178 Joiner Strip (to mount unit to the left of a 2424G) 212-8178 Joiner Strip (to mount unit to the right of a 2424G)
  • Page 80 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.3 Component Box, Computers, and Related Components Speaker mounts directly into component box.
  • Page 81 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.3 Component Box, Computers, and Related Components (cont.) ITEM PART # 824-1195 Component Box (KCF118GN and KCF118GP) 824-0941 Component Box (KCF118N and KCF118P) 807-4114 Relay, DPDT, 24VAC...
  • Page 82 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.4 Drain Valve, Oil Return, and Related Components ITEM PART # 106-0754SP Oil Return Handle Assembly Nipple, ⅜" NPT x 1 ½", Black Tube 813-0644 Bushing, ½" to ⅜" NPT, Hex, BM...
  • Page 83 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.4 Drain Valve, Oil Return, and Related Components (cont.) ITEM PART # 813-0298 Nipple, ½" NPT x 2", BM 813-0165 Elbow, Street, ½" NPT, 90° 813-0062 Elbow, ½" NPT, 90°, BM 813-0087 Nipple, ½"...
  • Page 84 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.5 Filter Pan and Related Components...
  • Page 85 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.5 Filter and Related Components (cont.) ITEM PART # Filter Components 823-4439 Pan, Filter 106-7331SP Grid, Wire 823-5422 Hold Down Ring 823-3736 Crumb Basket 823-4440 Lid, Filter Pan...
  • Page 86 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.6 Frypot and Related Components ITEM PART # 823-4884SP Frypot, Stainless Steel, with 1½" Drain 803-0149 Grid, Frypot 210-8387 Diffuser Assembly 200-1615 Support, Manifold 810-2151 Burner, Left...
  • Page 87 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.7 Gas Valves, Pilot Assemblies, and Related Components Non-CE Gas Valve(s) CE Gas Valve(s) 9-11...
  • Page 88 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.7 Gas Valves, Pilot Assemblies, and Related Components (cont.) ITEM PART # 807-3552 Gas Valve, Natural Gas, 24V (Non-CE) 807-3628 Gas Valve, LP, 24V (Non-CE) 806-6710SP Gas Valve, Natural Gas, 24V (CE)
  • Page 89 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.8 Over-the-Top Oil Return and Related Components 9-13...
  • Page 90 KSCF18G COOL ZONE SERIES GAS FRYERS CHAPTER 9: PARTS LIST: SINGLE UNITS (118G) 9.8 Over-the-Top Oil Return and Related Components (cont.) ITEM PART # 106-3347 Oil Return Assembly 810-0697 813-0003 813-0022 813-0062 813-0173 813-0247 813-0298 813-0463 813-0608 816-0596 823-3754 106-5230...
  • Page 91 Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Call Center) 1-318-219-7135 Price: $10.00 SERVICE HOTLINE 819-5712 PRINTED IN THE UNITED STATES 1-800-551-8633 MARCH 2007...

Table of Contents