Download Print this page

Frymaster 14 Series Operator's Manual page 77

Frymaster electric fryer operator's manual

Advertisement

Problem
MAINT FILTER
(Manual Filter) won't
start.
M2007 display shows
filter busy.
7.2.4 Auto Top-Off Problems
Problem
Frypots won't top off.
Fryer tops off cold. Incorrect setpoint.
One vat doesn't top off.
Probable Causes
Temperature too low.
Another filtration cycle is still in process.
Probable Causes
A. Fryer temperature too low.
B. Oil is too cold.
C. M2007 not readdressed after ATO
power lost.
A. Filter error exists.
B. Solenoid, pump, RTD or ATO issue.
Corrective Action
Ensure fryer is at setpoint before starting
MAINT FILTER.
A.
Wait until the previous filtration
cycle ends to start another filtration
cycle.
B.
A computer has an error. Using the
filter menu, try to perform a FILL
POT FROM DRAIN PAN on each
vat (see section 4.11.3 page 4-22).
Only computers with errors can
perform this function with a filter
busy error. Computer should clear
and return to normal operation once
complete.
Corrective Action
A. Fryer
setpoint.
B. Ensure that the oil in the JIB is
above 70°F (21°C).
C. Switch all M2007 computers off and
then on again to readdress system.
If problem persists c all 1-800-551-8633
for assistance.
Ensure setpoint is correct.
A. Clear filter error properly. When
change filter pad YES/NO is
displayed, do NOT press any button
until the pan has been removed for at
least two minutes. After two
minutes have elapsed, press YES.
Display returns to normal cook
mode. Filter error cleared, low vat
should begin to top off. If problem
persists c all 1-800-551-8633 for
assistance.
B. Call 1-800-551-8633 for assistance.
7-5
temperature
must
be
at

Hide quick links:

Advertisement

loading

This manual is also suitable for: