Problem
M2007 displays
CHANGE FILTER
PAD with yellow and
blue LED's flashing.
M2007 displays
SERVICE
REQUIRED.
M2007 displays
BUSY WAIT 30
SECONDS.
7.2.3 Filtration Problems
Problem
Filter pump won't start
or pump stops during
filtering.
Drain valve or return
valve stays open.
M2007 display shows
chk pan.
Auto filtration won't
start.
Fryer filters after each
cook cycle.
Probable Causes
No was chosen on previous CHANGE
FILTER PAD prompt.
Filter error was not cleared properly.
Action chosen while MIB is resetting.
Probable Causes
A. Power cord is not plugged in or circuit
breaker is tripped.
B. Pump motor has overheated causing
the thermal overload switch to trip.
C. Blockage in filter pump.
A. AIF board has failed.
B. Actuator has failed.
A. Filter pan is not fully set into fryer.
B. Missing filter pan magnet.
C. Defective filter pan switch.
A. Check that MIB board is not in manual
mode.
B. Check to see that the MIB cover is not
damaged and depressing the buttons.
C. Filter relay has failed.
D. AIF is set to enabled, blue light
doesn't light.
A. Filter after setting incorrect or software
update issue.
Corrective Action
Change filter pad if needed and ensure
the pan is removed from cabinet for at
least TWO minutes. Then press
YES) to clear message.
Call 1-800-551-8633 for assistance.
Wait until MIB displays "A".
Corrective Action
A. Verify that the power cord is fully
plugged in and the circuit breaker is
not tripped.
B. If the motor is too hot to touch for
more than a few seconds, the
thermal
probably tripped. Allow the motor
to cool at least 45 minutes then press
the Pump Reset Switch.
C. Call 1-800-551-8633 for
assistance.
Call 1-800-551-8633 for assistance.
A. Pull filter pan out and fully reinsert
into fryer.
B. Ensure the filter pan magnet is in
place and replace if missing.
C. If the filter pan magnet is fully
against the switch and computer
continues to display chk pan,
switch is possibly defective.
A. Ensure MIB board is in "A"
automatic mode. Press the reset
button.
B. Remove and replace cover and see
if filtration will start.
C. Call 1-800-551-8633 for
assistance.
D. Set AIF in Level 1 to disabled.
A. Change or overwrite the filter after
setting by re-entering the filter after
value in level two. Ensure that the
down arrow is pressed after entering
the value to save the setting (see
section 4.13.5 on page 4-36).
7-4
(1
overload
switch
has