Simrad AP50 Instruction Manual page 92

Hide thumbs Also See for AP50:
Table of Contents

Advertisement

Simrad AP50 Autopilot
MODEL
MOTOR
VOLTS
MLD200
12
HLD350
12
HLD2000L
12
HLD2000D
24
HLD2000LD
24
MSD50
12
Steering Gear Interface: Connects to Quadrant or Tiller.
Note !
1. The motor voltage is stepped down by the junction unit when
2. The specified junction unit is necessary to achieve maximum drive
3. Recommended operational thrust or torque is 70% of the listed
4. Typical average power consumption is 40% of the listed maximum
90
LINEAR DRIVE UNITS
JUNCTION
MAX.
UNIT
STROKE
mm (in.)
J50
300 (11.8)
J50
200 (7.9)
J50
340 (13.4)
J50
200 (7.9)
J50
340 (13.4)
J50
190 (17.5)
Table 4-3 Linear Drive Units
operating from 24 V or 32 V Mains (except for RPU1 and RPU3).
unit capacity.
value.
value.
PEAK
MAX.
THRUST
RUDDER
kg (lb.)
TORQUE
Nm
(lb./in.)
(30% load)
200
490
(440)
(4350)
350
610
(770)
(5400)
500
1460
(1100)
(12850)
1050
1800
(2310)
(15900)
1050
3180
(2310)
(28000)
60
-
(132)
HARD-
PWR.
TILLER
OVER
CON-
ARM
TIME
SUMP.
mm
sec.
(in.)
15
1.5-6 A
263
(10.4)
12
2.5-8 A
175
(6.9)
19
3-10 A
298
(11.7)
11
3-10 A
175
(6.9)
19
3-10 A
298
(11.7)
15
0.8-2 A
20221032B
-

Advertisement

Table of Contents
loading