Toshiba e-STUDIO6520c Imaging Manual page 280

Hide thumbs Also See for e-STUDIO6520c:
Table of Contents

Advertisement

5. Scanning-specific Adjustments
Procedures
* You can start with any of the procedures. But it is recommended to perform the procedures in order, as listed
below. You can use one procedure in conjunction with another. But if this changes the image quality more
than required or loses the effectiveness of the adjustment, restore the settings made in the previously used
procedure to the original ones. Then use other procedures.
* Both the service technician and the user can use procedure (1).
* Only the service technician must use procedure (2).
(1) When scanning the original, press the [COMMON SETTING] button on the Control Panel. Press the [+]
button to increase the sharpness intensity.
After increasing the sharpness intensity, scan the original and check the scanned-in image quality.
With the sharpness intensity set to the maximum, if further image quality adjustments are still necessary, the
service technician must use the next procedure.
(2) Enter adjustment mode [05]. Change the values for codes [1086 to 1088] and [840 to 843] to adjust the
sharpness intensity.
Color mode
Original mode [05] code
Text/Photo
Black
Full color
Printed image
Gray scale
* Setting "0" provides the softest image, while setting "255" provides the sharpest image.
Caution after the adjustment
The adjustment may possibly cause moiré. In addition, when text and thin lines in a light-colored background
are scanned, the background around the text or line may be eliminated. Therefore, carefully perform the
adjustment, while checking the scanned-in image.
e-STUDIO5520C/6520C/6530C
Recommended value
05-840
Text
05-841
Photo
05-842
Text
05-1086
Set a value larger than 128.
05-1087
Photo
05-1088
---
05-843
5-14
Acceptable
value range
0 to 255
© 2008 TOSHIBA TEC CORPORATION All rights reserved
Default
128

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio5520cE-studio6530c

Table of Contents