To Have Uniform Variations in the Image Quality after Return from the Auto Power Save Mode:
Change the value of the [08] code [571] to change the conditions for starting image quality control (shorten
the period of time the MFP is left unused) after the MFP was recovered from the auto power save mode, so
that the image quality control will be easily performed.
Value for
Period of time the MFP is left unused before starting image quality control
08-571
3 minutes or longer (image quality control is performed before the paused job is
0
resumed)
5 minutes or longer (image quality control is performed before the paused job is
1
resumed)
7 minutes or longer (image quality control is performed before the paused job is
2
resumed)
10 minutes or longer (image quality control is performed before the paused job is
3
resumed)
15 minutes or longer (image quality control is performed before the paused job is
4
resumed)
20 minutes or longer (image quality control is performed before the paused job is
5
resumed)
30 minutes or longer (image quality control is performed before the paused job is
6
resumed)
45 minutes or longer (image quality control is performed before the paused job is
7
resumed)
60 minutes or longer (image quality control is performed before the paused job is
8
resumed)
90 minutes or longer (image quality control is performed before the paused job is
9
resumed)
120 minutes or longer (image quality control is performed before the paused job is
10
resumed)
150 minutes or longer (default value - image quality control is performed before the
11
paused job is resumed)
180 minutes or longer (image quality control is performed before the paused job is
12
resumed)
240 minutes or longer (image quality control is performed before the paused job is
13
resumed)
300 minutes or longer (image quality control is performed before the paused job is
14
resumed)
360 minutes or longer (image quality control is performed before the paused job is
15
resumed)
<Note>
Do not disable the Auto shut off mode timer setting ("0" is set for 08-206) while the Auto
power save timer setting is set to invalid ("0" is set for 08-205). If both settings are set to
invalid, this equipment does not enter the energy saving mode so it is always in the ready
status. Due to this, image quality control according to the period of time the MFP is left
unused is not performed regardless of the setting value of 08-571.
• After setting the value for code 08-571, forcibly perform image quality control, as follows:
Enter adjustment mode [05], select code [396], and then press the [START] button.
e-STUDIO5520C/6520C/6530C
1. General Adjustments – Copying, Printing and e-Filing (Output from Box)