4.1 Parameter Lists

4.1.1
Parameter lists
Func-
Parameter
tion
Number
0
Torque boost (Note 1)
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
11
DC injection brake operation time
12
DC injection brake voltage
13
Starting frequency
14
Load pattern selection (Note 1)
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High-speed maximum frequency
19
Base frequency voltage (Note 1)
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double
speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
28
Multi-speed input compensation
29
Acceleration/deceleration pattern
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for
43
reverse rotation
Name
Setting Range
0 to 30%
0 to 120Hz
0 to 120Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600 s/
0 to 360 s
0 to 3600 s/
0 to 360 s
0 to 500A
0 to 120Hz, 9999
0 to 10 s, 8888
0 to 30%
0 to 60Hz
0 to 5
0 to 400Hz
0 to 3600 s/
0 to 360 s
120 to 400Hz
0 to 1000V, 8888, 9999
1 to 400Hz
0 to 200%, 9999
0 to 200%, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0, 1
0, 1, 2, 3
0, 1, 2
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0,1 to 9998
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
62
Minimum
Factory Setting
Setting
Increments
0.1%
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.1 s/
0.01 s
0.1 s/
0.01 s
0.01A
0.01Hz
0.1 s
0.1%
4%/2% (Note 1)
0.01Hz
1
0.01Hz
0.1 s/
0.01 s
0,2
1
0.01Hz
0.1V
0.01Hz
0,1
1
0.1%
0.1%
0.01Hz
0.01Hz
0.01Hz
0.01Hz
1
1
1
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
1
0.1%
0.01Hz
0.01Hz
PARAMETERS
Refer
Customer
To
<EC Version>
setting
Page:
6%/4%/3%/2%
71
(Note 9)
120Hz
72
0Hz
72
60Hz <50Hz>
73
60Hz
74
30Hz
74
10Hz
74
5 s/15 s
75
(Note 1)
5 s/15 s
75
(Note 1)
Rated output
76
current
3Hz
77
0.5 s
77
77
0.5Hz
78
0
79
5Hz
80
0.5 s
80
0
81
120Hz
72
9999 <8888>
73
60Hz <50Hz>
75
0
75
150%
82
9999
82
9999
74
9999
74
9999
74
9999
74
0
83
0
84
0
85
9999
86
9999
86
9999
86
9999
86
9999
86
9999
86
0
87
10%
88
6Hz
88
9999
88

Hide quick links: