Mitsubishi Electric FR-A500 Instruction Manual page 165

Transistorized inverter
Hide thumbs Also See for FR-A500:
Table of Contents

Advertisement

<Setting>
Refer to the following list and set the parameters:
Signal
Setting
Name
0
RL
1
RM
2
RH
3
RT
4
AU
5
JOG
6
CS
7
OH
8
REX
9
X9
10
X10
11
X11
12
X12
13
X13
14
X14
15
BRI
16
X16
17
X17
18
X18
19
X19
20
X20
22
X22
23
LX
9999
*: When Pr. 59 = "1 or 2", Pr. 79 = "5", and Pr. 270 = "1 or 3", the functions of the RL, RM, RH and RT signals change as listed above.
**: Operated when the relay contact "opens".
Functions
Pr. 59 = 0
Low-speed operation command
Pr. 59 = 1, 2*
Remote setting (setting clear)
Programmed operation group
Pr. 79 = 5
*
selection
Pr. 270 = 1, 3
Stop-on-contact selection 0
Pr. 59 = 0
Middle-speed operation command
Pr. 59 = 1, 2*
Remote setting (deceleration)
Programmed operation group
Pr. 79 = 5
selection
Pr. 59 = 0
High-speed operation command
Pr. 59 = 1, 2*
Remote setting (acceleration)
Programmed operation group
Pr. 79 = 5
selection
Second function selection (Note 7)
Pr.270 = 1, 3
*
Stop-on-contact selection 1
Current input selection
Jog operation selection
Automatic restart after instantaneous power failure selection
External thermal relay input**
The externally provided overheat protection thermal relay,
motor-embedded temperature, etc. is operated to stop the
inverter.
15-speed selection (combination with RL, RM, RH)
Third function
FR-HC, FR-CV connection (inverter operation enable)
FR-HC connection (instantaneous power failure detection)
(Only when FR-A5NR option is fitted)
PU operation external interlock
External DC injection brake start
PID control valid terminal
Brake opening completion signal
PU-external operation switchover
Load pattern selection forward/reverse rotation boost
Advanced magnetic flux vector-V/F switch-over (V/F control is
executed when X18 is on)
Load torque high-speed frequency
S-pattern acceleration/deceleration C switch-over terminal
(only when FR-A5AP option is fitted)
Orientation command (Note 8) (only when FR-A5AP option is
fitted)
Pre-excitation (Note 9) (only when FR-A5AP option is fitted)
No function
Pr. 4 to Pr. 6
Pr. 24 to Pr. 27
Pr. 232 to Pr. 239
Pr. 59
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
Pr. 270, Pr. 275, Pr. 276
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to
Pr. 239
Pr. 59
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to
Pr. 239
Pr. 59
Pr. 79, Pr. 200, Pr. 201 to Pr. 210, Pr. 211
to Pr. 220, Pr. 221 to Pr. 230, Pr. 231
Pr. 44 to Pr. 50
Pr. 270, Pr. 275, Pr. 276
Refer to page 13
Pr. 15, Pr. 16
Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr. 611
Refer to page 192
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 110 to Pr. 116
Pr. 30, Pr. 70
Pr. 30, Pr. 70
Pr. 79
Pr. 10 to Pr. 12
Pr. 128 to Pr. 134
Pr. 278 to Pr. 285
Pr. 79
Pr. 14
Pr. 80, Pr. 81, Pr. 89
Pr. 271 to Pr. 274
Pr. 380 to Pr. 383
Pr. 350 to Pr. 369
Pr. 80, Pr.81, Pr. 359, Pr. 369, Pr. 370
156
PARAMETERS
Relevant Parameters

Hide quick links:

Advertisement

Table of Contents
loading