Venting - Rigid Pipe Venting Systems; Horizontal Or Vertical Terminations - Regency P33-LP3 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

The minimum components required for a basic
horizontal termination are:
1
AstroCap Horizontal Termination Cap
1
45
o
Elbow
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create
a level surface to mount the vent terminal. The
Terminal must not be recessed into siding.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Alternate Hori-
zontal Termi-
nation Caps
TM
The FPI AstroCap
and FPI Riser Vent terminal is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS,
American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI
Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace
RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Vertical
Terminal
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
Flat Wall Installation
Max. Wall
Thickness (inches)
10-1/4"
13-1/4"
12-1/4" - 15-7/8"
11" - 14-5/8" Adj. Pipe
18-1/4" - 25-1/4"
11" - 14-5/8" Adj. Pipe
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
o
90 Elbow
24" (610mm)
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
o
45 Elbow
Rigid Pipe Adaptor
Vent Length
Required (inches)
7-1/4"
6"
9"
12"
TM
, and FPI AstroCap
INSTALLATION
Vinyl Siding
Standoff (Optional)
Horizontal
Termination
Cap
Wall Thimble
Termination Cap
Vinyl Siding
Standoff (Optional)
Wall Thimble
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek for
using a Dura-Vent Flue Adaptor in conjunction
with Selkirk Direct-Temp and Ameri Vent Direct
venting systems. Use of these systems with the
Direct Vent GS starting collar is deemed accept-
able and does not affect the Intertek WHI listing
of components.
When using piping other than Simpson
Dura-Vent, 3 screws must be used to
secure rigid pipe to adaptor.
TM
are the proprietary trademarks of FPI Fireplace
Horizontal
and FPI
TM