INSTALLATION
The P33-3 is approved for a maximum 40 ft. straight vertical, with rigid pipe
vent systems for Propane and Natural Gas.
The shaded area in the diagram shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for
Propane and Natural Gas. Maximum two 45
Vent must be supported at offsets.
Firestops are required at each fl oor level and whenever passing
through a wall.
Maintain clearances to combustibles.
o
elbows allowed.
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace