LED Indicators Fig. 6
The operators include a self-diagnostic circuit board using troubleshooting LED
indicators to signal the technician of a problem.
LED
ON
STB ENABLED
STB
ENABLE
POWER AVAILABLE
+ 24 VOLTS
DC
EXT
INTLK ENABLED
INTLK
HOIST
INTLK ENABLED
INTLK
GCL-GCX
Counter Door Operator
OFF
STB DISABLED
1. CHECK AC POWER SUPPLY
2. CHECK FUSES
1. INTLK SWITCH OPEN
2. CHECK POWER SUPPLY
3. CHECK MAIN POWER FUSE
4. CHECK SECONDARY FUSE (2A)
1. INTLK SWITCH OPEN
2. HOIST RELEASE NEEDS RESET
3. INTLK CONNECTOR NOT PLUGGED IN
4. INTERLOCK DEFECTIVE