External Radio Installation
To Add the External Radio
1) Plug the pigtail with the 3-terminal strip attached (provided) onto the
plug connector marked "EXT RAD." Fig. 12.
2) Make wiring connections to the terminal strip per the diagram below.
PWR
20-40 VDC @ 315mA
MAX CURRENT
EXT RAD O CONNECTOR
RELAY
NOM
+ 24VDC
GND
RADIO
RADIO
CONNECTOR
Figure 12
GCL-GCX
Counter Door Operator
CAL
SET
CROLL
RUN
CLR
CROLL
TB
NAB
+ 4
AC
XT
N LK
OI T
S
S
B
S B
S B
S
S
Y
N LK
www.geniecompany.com
IMPORTANT
SAFETY INSTRUCTIONS
WARNING - To reduce the risk
of severe injury or death:
1) READ AND FOLLOW ALL INSTRUCTIONS.
2) Never let children operate or play with door controls. Keep the
remote control (where provided) away from children.
3) Personnel should keep away from a door in motion and keep
the moving door in sight until it is completely closed or opened.
NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.
4) Test the door's safety features at least once a month. After
adjusting either the force or the limit of travel, retest the door
operator's safety features.
5) For products having a manual release, if possible, use the
manual release only when the door is closed. Use caution when
operating the release while the door is open. Weak or broken
springs may cause the door to fall rapidly, causing severe injury
or death.
6) KEEP DOOR PROPERLY OPERATING AND BALANCED. See Door
Manufacturer's Owner's Manual. An improperly operating or
improperly balanced door could cause severe injury or death.
Have only trained door systems technicians make repairs to
cables, spring assemblies, other hardware and any wooden
blocks or like items to which they may be attached.
7) SAVE THESE INSTRUCTIONS.
08-12