Section 5: Troubleshooting; Troubleshooting Led's - Genie RMZ Z Series Manual

Sidemount operator
Table of Contents

Advertisement

RMZ operators include a self-diagnostic circuit board using troubleshooting LED indicators to signal the
technician of a problem.
TROUBLESHOOTING
LEDs
HOIST
EXTERNAL
INTERLOCK
INTERLOCK
ON
ON
OFF
ON
OFF
OFF
OFF
OFF

Section 5: Troubleshooting

STB
ENAB
+ 24
VDC
EXT
INTLK
HOIST
INTLK
DETAIL

TROUBLESHOOTING LED's

+24VDC
STB
ENABLE
OFF
ON
ON
ON
ON
OFF
./&
./&
000-C.0
000-C.0
00"2,
00"2,
.1"-
&'.5"
5,.1
!-/
<B$,-
5,$
5,$
5)8",9
5)8",9
+-,'(
+-,'(
INDICATION
STB Disabled
STB Enabled
Normal Operating Condition
Hoist Interlock Switch Open:
• Hoist release requires reset
• Hoist interlock connector not plugged in
• Hoist interlock defective
External Interlock Open
Power Supply Problem:
• Check AC power supply
• Check main power fuse
• Check secondary fuse (2A)
STB
ENAB
'<
-
+ 24
VAC
EXT
INTLK
HOIST
INTLK
Sec-5.1