REPLACE DATA (PARTIAL EDIT)
FUNCTION
To replace a specified area of the previous label with new data. This command will cause the
previous label to print along with any changes specified within the current data stream.
FORMAT
<ESC>0 (<ESC>zero)
Must follow <ESC>A and precede all other print data
EXAMPLE
<ESC>A
<ESC>H0025<ESC>V0020<ESC>WB0Company Name
<ESC>H0025<ESC>V0085<ESC>WB1SATO
<ESC>H0025<ESC>V0150<ESC>WL0SATO
<ESC>H0025<ESC>V0215<ESC>WL1SATO
<ESC>Q1<ESC>Z
<ESC>A
<ESC>0<ESC>H0025<ESC>V0020<ESC>WB0SATO
<ESC>Q1
<ESC>Z
OUTPUT
(4-10)
NOTES
Specify the exact same parameters for the image to be replaced as were specified in the original data
stream; including rotation, expansion, pitch, etc. This will ensure the new data will exactly replace the
old image. If the replacement data contains fewer characters than the old data, then the characters not
replaced will still be printed.
This command will not function if the power has been cycled off and back on since the last label was
printed.
Proportional Pitch text cannot be used with this command.
E/Pro Programming Reference
Unit 4: Standard Command Codes
4-18
PN: 9001096E