Unit 4: Standard Command Codes
REPLACE DATA (PARTIAL EDIT)
FUNCTION
To replace a specified area of the previous label with new data. This command will
cause the previous label to print along with any changes specified within the current
data stream.
FORMAT
<ESC>0 (<ESC>zero)
Must follow <ESC>A and precede all other print data
EXAMPLE
<ESC>A
<ESC>H0025<ESC>V0020<ESC>WB0Company Name
<ESC>H0025<ESC>V0085<ESC>WB1SATO
<ESC>H0025<ESC>V0150<ESC>WL0SATO
<ESC>H0025<ESC>V0215<ESC>WL1SATO
<ESC>Q1<ESC>Z
<ESC>A
<ESC>0<ESC>H0025<ESC>V0020<ESC>WB0SATO
<ESC>Q1
<ESC>Z
OUTPUT
(4-12)
NOTES
Specify the exact same parameters for the image to be replaced as were specified in
the original data stream; including rotation, expansion, pitch, etc. This will ensure the
new data will exactly replace the old image. If the replacement data contains fewer
characters than the old data, then the characters not replaced will still be printed.
This command will not function if the power has been cycled off and back on since the
last label was printed.
Proportional Pitch text cannot be used with this command.
SATO E+ Programming Reference
PN 9001149A
Page 4-17