2D12 (MICRO PDF417)
FUNCTION
Specifies Micro PDF417 of 2D code.
FORMAT
<ESC>2D12,aa,bb,c,dd,(e)
Between <ESC>A and <ESC>Z but following <ESC>H and <ESC>V.
EXAMPLE
Example - Minimum module width: 02 dots, Minimum module height: 04 dots, Words per
line: 01, Lines per symbol: 14.
<ESC>A
<ESC>V100<ESC>H100
<ESC>2D12,02,04,1,14
<ESC>DN0010,0123456789
<ESC>Q2
<ESC>Z
OUTPUT
(4-47)
NOTES
<ESC>DNmmmm,n...n (when Binary mode is set to 1)
<ESC>DNn...n (when binary mode is set to 0)
The quantity of lines per symbol is set by the quantity of data code words per line. When the data
includes alphabet (uppercase/lowercase letters), numeric and control codes, the quantity of characters
used will affect the maximum data quantity.
Refer to Appendix: Reference Tables 30 and 31 for additional information.
E/Pro Programming Reference
Unit 4: Standard Command Codes
<ESC>DNmmmm,n...n
a
= Minimum module width (01 to 09 dots)
b
= Minimum module height (01 to 24 dots)
c
= Quantity of data code words per line (1 to 4 columns)
d
= Quantity of lines per symbol (4 to 44)
e
= Binary mode
0: Normal (if digit is omitted, the default is zero)
1: Binary
m
= Data size (0001 to 0366 bytes)
n
= Print data