UPC-A BARCODE (NO HRI)
FUNCTION
Specifies UPC-A Barcode with start/end bar in the same length with guard bar.
FORMAT
<ESC>BL
EXAMPLE
Barcode type: UPC-A, Narrow bar width: 03, Barcode height: 120, Print data: 01234567890
<ESC>A
<ESC>V100<ESC>H100<ESC>BLH0312001234567890
<ESC>Q2
<ESC>Z
OUTPUT
NOTES
E/Pro Programming Reference
Unit 4: Standard Command Codes
abbcccn~n
a
=
Barcode type = H: UPC-A("H"Fixed)
b
=
Narrow bar width = Valid range : 01 to 12 dots
c
=
Barcode height = 001 to 999 dots
=
n
Print data = Data: 11 digits fixed
1. This command supports UPC-A. Selecting barcode type other than "H" will result in a
command error.
2. Refer to the following settings.
G
u
a
d r
b
r a
Y
e
s
3. If a parameter is specified out of the range, its behavior will not be supported.
4. When using command <ESC>D to print UPC-A, the character bars will be all in the same
length. The command <ESC>BL will print the start bar and end bar in the same length as that of
guard bars.
Barcode setting
H
I R
N
o
4-57
R
t a
o i
i F
e x
d
PN: 9001096E