COMMAND QUICK REFERENCE
INSTRUCTION
/Nbb,cc
2D10
2D12
E/Pro Programming Reference
Unit 3: Code Quick Reference
Field, Store. To store a field in the memory card.
bb
=
Field number (01 to 99)
cc
=
Quantity of characters in the field
2D Code. Specifies PDF417 of 2D code.
a
=
Minimum module width (01 to 09 dots)
b
=
Minimum module height (01 to 24 dots)
c
=
Security level (0 to 8)
=
Quantity of data code words per line (01 to 30)
d
00: Automatic (width varies on data quantity specified)
e
=
Quantity of lines per symbol (03 to 90)
00: Automatic (width varies on data quantity specified)
f
=
Code type
0: Normal (if digit is omitted, the default is zero)
1: Truncated scale
m
=
Data size (1 to 2681 bytes)
=
Print data
n
2D Code. Specifies Micro PDF417 of 2D code.
=
Minimum module width (01 to 09 dots)
a
b
=
Minimum module height (01 to 24 dots)
c
=
Quantity of data code words per line (1 to 4 columns)
d
=
Quantity of lines per symbol (4 to 44 lines)
=
Binary mode
e
0: Normal (if digit is omitted, the default is zero)
1: Binary
=
Data size (0001 to 0366 bytes)
m
n
=
Print data