HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 86

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Maximum Capacity
Hardware Configuration
– Two disk array controllers connected directly to host Fibre Channel adapters
– Three disk enclosures with ten 73 GByte disks each (30 disks total)
– Disk enclosures configured for split-bus mode (two SCSI channels per enclosure)
LUN Configuration
– Ten RAID 5 LUNs, each comprising three disks (2 data + 1 parity).
– Each disk in a LUN is in a separate enclosure.
High Availability
– Handles a single disk failure, single controller, single channel, single BCC, or a single
disk enclosure failure
– Expansion requires powering down the disk array, recabling the array to a full bus
configuration, rebinding the LUNs, and restoring all data
Disk Capacity
– Maximum capacity 2190 GBytes
– Usable capacity 1460 GBytes
Recommended Disk Array Configurations
86

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents