Information for Controller A - 000A00A0B80673A6:
Controller Status
Controller Mode
Vendor ID
Product ID
Serial Number
Firmware Revision
Boot Revision
HP Revision
Loop ID
AL_PA
Preferred AL_PA
Controller Date
Controller Time
Cache Battery Age
NVSRAM Checksum
Information for Controller B - 000A00A0B80673A6:
Controller Status
Controller Mode
Vendor ID
Product ID
Serial Number
Firmware Revision
Boot Revision
HP Revision
Loop ID
AL_PA
Preferred AL_PA
Controller Date
Controller Time
Cache Battery Age
NVSRAM Checksum
Information for Disk System 1 (USSA02010592), Controller B:
SCSI Channel
Thumbwheel Setting
Controller Status
Vendor ID
Product ID
Serial Number
Firmware Revision
Information for Disk System 1 (USSA02010592), Controller A:
SCSI Channel
Thumbwheel Setting
Controller Status
Vendor ID
Product ID
Serial Number
i
Managing the Disk Array Using Array Manager 60
286
= GOOD
= ACTIVE
= HP
= A5277A
= 1T00310110
= 04000304
= 04000200
= HP08
= 5
= 0xE0
= 0xE0
= 05/08/2000
= 13:38:53
= 0 to 89 days
= 0x353181DF
= GOOD
= ACTIVE
= HP
= A5277A
= 1T90510188
= 04000304
= 04000200
= HP08
= 4
= 0xE1
= 0xE1
= 05/08/2000
= 13:38:54
= 0 to 89 days
= 0x353181DF
= 2
= 0
= GOOD
= HP
= A5294A
= USSA02010649
= HP04
= 1
= 0
= GOOD
= HP
= A5294A
= USSA02010592
i i
Controller Information - make sure the
following conditions are met:
- Both controllers should be ACTIVE
- The Loop ID must be unique for each
controller
- The three levels of firmware revisions must
be identical for each controller
Disk Enclosure Information -
make sure the following
conditions are met:
- The status of both controllers
(BCCs) should be GOOD
- The Thumbwheel Setting
must be the same for each
controller
- The Thumbwheel Setting
should correspond to the
enclosure position in the rack.
Uppermost enclosure set to 0,