HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 119

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Table 10
High Availability Topology Error Recovery (cont'd)
Failing
Continue
component
after failure
Fibre
No on path to
Channel
failed cable;
cable
Yes if array has
dual controller
modules and
alternate paths
have been
configured
What happens and how to recover
I/O operations fail along the path through the failed cable. If the
host has two Fibre Channel adapters connected to a dual-controller
module disk array, the array can be accessed through the
operational path if primary and alternate paths have been
configured in LVM. If so, LVM switches automatically and
transparently to the alternate path. The authorized service provider
hot-swaps the failed cable.
Topologies for HP-UX
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents