HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 328

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
0C
00
0C
01
0C
80
0C
81
Status Conditions and Sense Code Information
328
Interpretation
If the accompanying sense key = 4, error is interrupted as
follows:
Unrecovered Write Error
Data could not be written to media due to an unrecoverable
RAM, battery or drive error.
If the accompanying sense key = 6, error is interrupted as
follows:
Caching Disabled
Data caching has been disabled due to loss of mirroring capa-
bility or low battery capacity.
Write Error Recovered with Auto Reallocation
The controller recovered a write operation to a drive and no fur-
ther action is required by the host. Auto reallocation may not
have been used, but this is the only standard ASC/ ASCQ that
tells the initiator that no further actions are required by the
driver.
Unrecovered Write Error Due to Non-Volatile Cache Failure
The subsystem Non-Volatile cache memory recovery mecha-
nisms failed after a power cycle or reset. This is possibly due to
some combination of battery failure, alternate controller failure
or foreign controller.
User data may have been lost.
Deferred Unrecoverable Error Due to Memory Failure
Recovery from a Data Cache error was unsuccessful.
User data may have been lost.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents