Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
95
02
98
01
98
02
98
03
A0
00
A1
00
A4
00
Status Conditions and Sense Code Information
342
Interpretation
Controller Removal/Replacement Detected or Alternate Con-
troller Released from Reset
The controller detected the activation of the signal/signals used
to indicate that the alternate controller has been removed or
replaced.
The controller has determined that there are multiple sub-enclo-
sures with the same ID value selected.
Sub-enclosure with redundant ESMs specifying different Tray
levels.
Sub-enclosure ESMs have different firmware levels
Write Back Caching Could Not Be Enabled
The controller could not perform write back caching due to a
battery failure or discharge, Two Minute Warning signal from
the UPS, or an ICON failure.
Write Back Caching Could Not Be Enabled - RDAC Cache Size
Mismatch
The controller could not perform write back caching due to the
cache sizes of the two controllers in the RDAC pair not match-
ing.
Global Hot Spare Size Insufficient for All Drives in Subsystem.
A defined Global Hot Spare is not large enough to cover all of
the drives present in the subsystem. Failure of a drive larger
than the Global Hot Spare will not be covered by the Global Hot
Spare drive.