2.
Bind a LUN with the new disks using the management tool of your choice,:
– To use SAM, see
– To use Array Manager 60, see
– To use STM, see
After binding a LUN, you must execute the insf -e command to install special
Note
device files on the LUN. This makes the LUN usable by the operating system.
3.
Disable WCE on the disk modules using the following command:
amutil -w <ArrayID>
See
"Disabling Disk Module Write Cache Enable (WCE)" on page 302
information.
Moving Disks from One Disk Array to Another
Before moving disks from one array to another, ensure that there is no
C
AUTION
important data on the disks. All data on the disks will be lost when they are
installed in the new disk array.
If you have more than one HP SureStore E Disk Array FC60, you can move disks from one
array to another to balance capacity. The disks can be installed in the new array with
power on and they will be treated as new disks. Any important data on the disks should be
backed up before the disks are moved.
Note
Can I move a disk module within the array with power on?
You should not move disks within the array with power on. Moving a disk from
one slot to another will erase the data on the disk module.
"Binding a LUN" on page 267
"Binding a LUN" on page 289
"Binding a LUN" on page 314
for more
Adding Capacity to the Disk Array