Interpreting Component Status Values (Hp-Ux Only) - HP Surestore Disk Array 12h - And FC60 Advanced User's Manual

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

It is normal for the amber Fault LED on a component to go on briefly when the
Note
component initially starts up. However, if the Fault LED remains on for more
than a few seconds, a fault has been detected.

Interpreting Component Status Values (HP-UX Only)

Common status terms have specific indications for various disk enclosure components.
The component status condition terminology used by Array Manager 60 (AM60) may differ
from that used by STM. Both terms are identified in
Table 51
Status Indications by Component
Component/Status
Disks
AM60: Good
Component is installed and no error conditions are known.
STM: Optimal
AM60: Critical
N/A
STM: Fault - 2
AM60: Non-critical
N/A
STM: Fault - 3
AM60: Not Installed
Component is not installed.
STM: Not Present
AM60: Unknown
N/A
STM: Fault - 0
Not Available
Component is installed without known errors, but has not been turned on
or set into operation; or the controller that owns reporting has failed.
Table
51.
Fans, Power
BCCs
Supplies
Hardware has failed.
BCC A and B
N/A
have different
firmware
versions.
N/A
N/A
SureStore E Disk System SC10 Troubleshooting
Sensors
Voltage/temperature
exceeds critical limit.
Voltage/temperature
exceeds warning limit.
Sensor has failed or
status is not available.
379

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents