Surestore E Disk System Sc10 Troubleshooting; Disk Enclosure Leds; Losing Lun 0 - HP Surestore Disk Array 12h - And FC60 Advanced User's Manual

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

SureStore E Disk System SC10 Troubleshooting

This section contains information on identifying and isolating problems with the Disk
System SC10 disk enclosure.

Disk Enclosure LEDs

Figure 93
shows the locations of the disk enclosure status LEDs.
operating LED states for all components within the disk enclosure.

Losing LUN 0

If LUN 0 becomes unavailable because of multiple disk failures, Array Manager 60 may not
be able to communicate with the disk array. If this occurs, replace the failed disks as
quickly as possible. When the disk are replaced it may be necessary to replace LUN 0,
recreating it in its original configuration.
If LUN 0 is lost, do not power off the disk array. Without LUN 0, the disk array
C
AUTION
will not operate normally when it is powered back on.