HP Surestore Disk Array 12h - And FC60 Advanced User's Manual page 284

Hp surestore e disk array fc60 - (english) advanced user's guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Figure 88
Disk Array Sample Status Output (amdsp)
Vendor ID
Product ID
Array ID
Array alias
-----------------------------------------
Array State
Server name
Array type
Mfg. Product Code
--- Disk space usage --------------------
Total physical
Allocated to LUNs
Used as Hot spare
Unallocated (avail for LUNs) = 0.0 GB
-----------------------------------------
Vendor ID
Product ID
Array ID
Array alias
-----------------------------------------
LUN
Status
---
-----------------
0
OPTIMAL
1
OPTIMAL
.
.
31
UTM:GOOD
LUN
WCE
RCD
CME
---
---
---
---
0
X
1
X
.
.
.
Total capacity of LUNs on controller A = 84.6 GB
Total capacity of LUNs on controller B = 50.8 GB
Total capacity of all configured LUNs = 135.4 GB
Managing the Disk Array Using Array Manager 60
284
= HP
= A5277A
= 000A00A0B80673A6
= Array1
= READY
= speedy
= 3
= 348-0040789
= 271.4 GB
= 135.4 GB
= 0.0 GB
= HP
= A5277A
= 000A00A0B80673A6
= Array1
Capacity
Ctrl
---------
----
16.9 GB
A
16.9 GB
B
LUN 31 is the default UTM LUN. GOOD status indicates the UTM is
enabled and operating normally. See note on page 283.
CWOB
WCA
RCA
----
---
---
X
X
X
X
X
X
RAID
Segment
Disks
----
-------
-----
LUN Information - the
1
4
1:0
status of each LUN should
3:0
be OPTIMAL
1
4
2:0
4:0
CMA
Cache Status for each LUN - all LUNs should
---
have the status values shown
X
X
LUNs should typically be distributed
between both controllers for best
performance. LUN ownership can be
reassigned to balance LUN usage.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array fc60

Table of Contents