Table 44
SCSI Sense Codes (cont'd)
Additional
Additional
Sense
Sense Code
Code
Qualifier
2F
00
31
01
32
00
3F
01
3F
0E
Status Conditions and Sense Code Information
332
Interpretation
Commands Cleared by Another Initiator
The controller received a Clear Queue message from another
initiator. This error is to notify the current initiator that the con-
troller cleared the current initiators commands if it had any out-
standing.
Format Command Failed
A Format Unit command issued to a drive returned an unrecov-
erable error.
Out of Alternates
A Re-assign Blocks command to a d rive failed.
Drive micro-code changed
Reported LUN's data has changed.
Previously LUN data reported via a Report LUNs command has
changed (due to LUN creation/deletion or controller hot swap)