Parameters - HP StoreFabric SN6500B Administrator's Manual

Fabric os administrator's guide, 7.1.0 (53-1002745-02, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

NOTE
Entering a --config command changes only those settings specified in the command; all others are
left alone. The only exceptions are for the -alert (restores alerts using recorded values) or -noalert
(disables all alerts) switches. This means that if you want alerts, you must specify what you want as
the -alert value for every bottleneckmon - -config -alert command. See
information about --config and -alert-related settings.
Use the following procedure to configure the bottleneck detection parameters:
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the bottleneckmon --config command to set the alerting and sub-second latency
To remove any port-specific alerting and sub-second latency criterion parameters and revert to the
switch-wide parameters, enter the bottleneckMon --configclear command. To remove and erase all
bottleneck alerts and their criteria, enter bottleneckMon --disable. See
detection on a switch"
Examples of applying and changing bottleneck detection parameters
The following examples show not just how to change various bottleneck detection parameters, but
how the changes made are retained when the next set of changes is made. For each example, after
the configuration command is run, the bottleneckMon
settings, which are bolded just for the examples.
Example 1: Setting time window, quiet time, and threshold values for an entire switch
This example sets the time window to 150 seconds, the quiet time to 150 seconds, the congestion
threshold to 0.7 (70%) and the latency threshold to 0.2 (20%) for the entire switch.
switch:admin> bottleneckmon --config -alert -time 150 -qtime 150 -cthresh 0.7
-lthresh 0.2
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold
Severity threshold
Switch-wide alerting parameters:
================================
Alerts
Latency threshold for alert
Congestion threshold for alert - 0.700
Averaging time for alert
Quiet time for alert
Example 2: Changing time window value for an entire switch
This changes the time window value to 200 seconds for the entire switch.
switch:admin> bottleneckmon --config -alert -time 200
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Fabric OS Administrator's Guide
53-1002745-02
criterion parameters.
on page 392 for more details.
Changing bottleneck detection parameters
status command is run to show the new
--
- 0.800
- 50.000
- Yes
- 0.200
- 150 seconds
- 150 seconds
13