UNIX systems

Checks if the following files exist:
For Data Protector 5.1 and earlier:
/etc/opt/omni/cell/cell_info
/etc/opt/omni/cell/installation_servers
/etc/opt/omni/users/UserList
/etc/opt/omni/users/ClassSpec
/etc/opt/omni/users/WebAccess
/etc/opt/omni/snmp/OVdests
/etc/opt/omni/snmp/OVfilter
/etc/opt/omni/options/global
/etc/opt/omni/options/trace
/etc/opt/omni/cell/cell_server
For Data Protector 5.5 and later:
/etc/opt/omni/server/cell/cell_info
/etc/opt/omni/server/cell/installation_servers
/etc/opt/omni/server/users/UserList
/etc/opt/omni/server/users/ClassSpec
/etc/opt/omni/server/users/WebAccess
/etc/opt/omni/server/snmp/OVdests
/etc/opt/omni/server/snmp/OVfilter
/etc/opt/omni/server/options/global
/etc/opt/omni/server/options/trace
/etc/opt/omni/client/cell_server
Polling interval: 15 minutes

Changing monitor parameters

Some of the monitors above have default parameters set in obspi.conf. This file
resides on the Data Protector Cell Manager along with the monitor executables. You
can alter the parameters by entering new values in obspi.conf.
The location of the file is:
68