Read these instructions
completely
and carefully.
[]
Connect
the Range
to the Gas Supply
Shut off the main gas supply valve before disconnecting
the old range and leave it off
until the new hookup has been completed. Don't forget to relight the pilot on other gas
appliances when you turn the gas back on
Because hard piping restricts movement of the
range, the use of a CSAInternational-certified
flexible metal appliance connectoris recommended
unlesslocal codes require a hard-piped connection.
Never use an old connector when installing a
new range. If the hard piping method is used, you
must carefully align the pipe;the range cannot be
moved after the connection is made.
To prevent gas leaks,put pipe joint compound on,
or wrap pipe thread tape with Teflon* around, all
male (external)pipe threads.
[]
Install a manual gas line shut-off valve in the
gas line in an easilg accessed location outside
of the range. Hake sure evergone operating
the range knows where and how to shut off
the gas supplg to the range.
[]
Install male 1/2" flare union adapter to
the 1/2" NPTinternal thread elbow at inlet
of regulatoE Use a backup wrench on the
regulator fitting to avoid damage.
When installing the range from the front,
remove the 90° elbow for easier installation.
[]
Install male 1/2" or 3/4" flare union adapter to
the NPTinternal thread of the manual shut-off
valve, taking care to backup the shut-off valve
to keep it from turning.
[]
Connect flexible metal appliance connector to
the adapter on the range. Position range to
permit connection at the shut-off valve.
[]
When all connections have been made, make
sure all range controls are in the off position
and turn on the main gas supplg valve.
Use a liquid leak detector at alljoints and
connections to check for leaks in the sgstem.
-& CAUTION: oo NOT USE A
FLAME TO CHECK FOR GAS LEAKS.
When using test pressuresgreater than 1/2 psig
to pressure test the gas supply sgstem of the
residence,disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressuresof 1/2 psig or less to test the
gas supply sgstem, simply isolate the range from
the gas supply sgstem bg closing the individual
shut-off valve,
*Teflon:Registeredtrademark of OuPont
Flexible Connector
Hookup
Adapter
__
!ie!i!Tii_:i
/
Installer:
Inform
I
_
Gas
the consumer of
I
1/2"or3/4"
h-€ill _-
shut-off
the location
of the
Gas pipe_
L_
_
valve
gas shut-off
valve.
Rigid Pipe Hookup Options
/45° Elbow "_k
9oo Elbow
N'ppe/
_
iron pipe
o_Jv_ _'_
_:_S_aU[: r
/
@_---
Union
Union
_
Nipple
III
Gas
I
_:L_
shut-off
Installer:Inform the consumerof
J/
IF]F-
valve
the location of the gas shut-off
TI_' _
1/2"
or 3/4"
valve.
Gas pipe
Alternate
_
Adapter
o
,,,- f (@)_"
o
Hookup
90
Elbow/"
_,
_
90
Elbow
_
.-
_1_
Nipple
Nipple --_
_-/^.,
I
I
1_i
_UlCK connect
_ll
_/or
union
t_
I¢ , .
Pressure
Gas
__
I
_
N,pple
,
shut-off _
[_
_
90 ° regu,ator
valve
_
_/ Elbow
!
1/2" or 3/4"
Gas pipe
90 ° Elbow
Installer: Inform the consumerof I
the location
of the gas shut-off
valve.