General Specifications

Electrical Specifications
Supply Voltage
Power Consumption
Ambient Temperature
Relative Humidity
DeviceNet Communication Specifications
Supported Connection
Baud Rates
Transfer Distance
Maximum Nodes
Data Length / Frame
Bus Access
Error Detection
Cable
Communications
Power Supply Voltage
* When thin cable is used for trunk line, the maximum network length is 100 m.
4
Item
5 V DC (supplied from a controller)
7 W
5-40 deg C
20-80%
Item
- I/O messaging connection
(Polling, Strove, Cyclic, Change of State)
- Explicit messaging connection
All connections are conformed to DeviceNet communication
protocol.
125 kbps, 250 kbps, 500 kbps
Baud Rates
500 kbps
250 kbps
125 kbps
64 (including master unit)
8 byte (The data can be divided and transferred.)
CSMA/NBA
CRC error / Duplicate node address check
5-wire cable dedicated to DeviceNet (2 wires for signal,
2 wires for power supply, 1 shield wire)
24 V DC (supplied from a connector)
Specification
Specification
Max. Network
Drop Length
Length
100 m
6 m or under
250 m *
6 m or under
500 m *
6 m or under
Total Drop
Line Length
39 m or under
78 m or under
156 m or under
Fieldbus I/O Rev.6