4. Troubleshooting (DeviceNet)
4.1.3.6 EPSON RC+ Master Configuration
For details of EPSON RC+ master configuration, refer to the section 2.5 DeviceNet Board
Installation.
The following section describes the procedure for verifying the scanner board condition with
applicomIO Console application.
4.1.3.6.1 Verifying applicomIO Console application condition
106
The status bar at the bottom of the window shows the applicomIO Console
application status. The status bar varies as shown below:
Character:
The address number of the scanner board is indicated with
characters. When the character "F" appears, the flash memory
on the board initialized the scanner board.
Background color: The background color indicates the scanner board status. For
details, refer to the table below.
Background Character
Gray
Black
Magenta
Black
Red
Black
Yellow
Black
Dark green
White
Green
Black
Status
Access to scanner board was failed.
After that, the status bar will not be renewed
automatically. To renew the status bar, right-click
the status bar and select Refresh.
The scanner board was initialized with an earlier
version applicomIO Console application.
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.
The scanner board was not initialized.
Initialize the scanner board to use it.
The scanner board was partially initialized.
This status happens only during network detection
and on-line actions.
Although the scanner board was initialized, it is
different than the currently opened configuration.
(Different version, etc.)
It is recommended that the scanner board be written
into the flash memory (reinitializing the scanner
board) again with the current version applicomIO
Console application.
This status happens only during network detection,
on-line actions, and diagnostic.
The scanner board was initialized properly and it is
no different with the currently opened
configuration.
This status happens only during network detection,
on-line actions, and diagnostics.