Epson EM07ZS1647F User Manual page 111

Rc+ option fieldbus i/o
Table of Contents

Advertisement

♦ Process Flowchart
Check for cable laying.
Check that
terminating resistors
are connected.
Normal
Turn OFF communications power supply.
Measure resistance
with tester.
50 to 70 Ω
Normal
See 4.1.3.2.
Fieldbus I/O Rev.6
Problem exists.
(Add terminating resistors.)
Out of 50 to 70 Ω (Error)
Resistance: over 70 Ω
Yes
Remove one terminating
resistor on either side.
Measure
Approx.
resistance at
120
connectors and
branch taps with
tester.
Other
Find the trouble point.
(1) Unconnected or loose connector
(2) Cable disconnection, etc.
4. Troubleshooting (DeviceNet)
No
Resistance: under 50 Ω
10 to 50 Ω
Check
for
connection
with terminating resistors
and branch taps.
(1) Three
or
more
terminating resistors
(2) Wrong
terminating
resistors, etc.
Under 10 Ω
Check for short
circuit between
signal wires.
Short
circuit
between signal
wires
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc+

Table of Contents