Epson EM07ZS1647F User Manual page 29

Rc+ option fieldbus i/o
Table of Contents

Advertisement

(2) Carefully expand the meshes of the braided shield.
Under the braided shield, there is one exposed bare
twisted shield wire other than the signal wires and
power wires that are wrapped with aluminum tape. The
shield wire is slightly harder than the mesh.
(3) Cut off the expanded braided shield and remove the
aluminum tape around the signal wires and power
wires. Then, strip the insulation from the signal wires
and power wires for a length sufficient to connect them
to crimp terminals.
Twist each stripped signal wire and power wire.
(4) Set the crimp terminal on the stripped part of the wire
and crimp it with a crimp tool. The following crimping
terminals are recommended products.
NICHIFU TC series
TMEV TC-0.5
TMEV TC-2-11
TMEV TC-1.25-11
Phoenix Contact AI series
AI 0.5-8WH
AI 0.25-8YE
AI 2.5-8BU
AI 1-8RD
(5) Wrap or cover the cable with vinyl tape or heat-shrink
tubing.
Loosen the screws securing the cables on the connector. If the screws are not loosened, the
NOTE
wires go into different openings on the rear of connector instead of the correct openings
and the wires cannot be secured.
(6) Ensure the correct connector orientation and insert the
signal wires and shield wire to their respective holes
on the connector.
As shown in the figure, insert the wires (black, blue,
shield, white, and red) into the holes in the order
named.
The following table shows the specified colors of the
cables.
a
b
c -
d
e
Fieldbus I/O Rev.6
Model Number
Model Number
Color
Details of Signal
Black
Communications Power
Supply (negative)
Blue
Signal (Low)
Shield
White
Signal (High)
Red
Communications Power
Supply (positive)
Specifications
For Thin Cable
For Thick Cable (power wire)
For Thick Cable (signal wire)
Specifications
For Thin Cable (power cable)
For Thin Cable (signal wire)
For Thick Cable (signal wire)
For Thick Cable (signal wire)
Wire Identity
V-
CAN L
S
CAN H
V+
2. Installation
Shield Wire
Peel the coverings in enough
length to connect the wires to
crimping terminals.
Special Tool
MH-32
Special Tool
CRIMPFOX UD6
Heat-shrinkable Tube, etc.
Insert wires in
this direction.
Insert the
a
connector
in this
b
direction.
e
d
c
Crimping
Terminal
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc+

Table of Contents