2.1.11.1

Coverage Measurement Procedures

The procedure for coverage measurement is as follows:
- Set range for coverage measurement
- Measure coverage
- Display measurement result

■ Setting Range for Coverage Measurement

Use the SET COVERAGE command to set the measurement range. The measurement range can be set
only within the area defined as the debug area. Up to 32 ranges can be specified.
By specifying /AUTOMATIC for the command qualifier, the code area for the loaded module is set
automatically. However, the library code area is not set when the C/C++ compiler library is linked.
[Example]
>SET COVERAGE FF000000 .. FFFFFFFF
■ Measuring Coverage
When preparing for coverage measurement, execute the program.
Measurement starts when the program is executed by using the GO, STEP, or CALL command.

■ Displaying Coverage Measurement Result

To display the measurement result, use the SHOW COVERAGE command. The following can be
displayed:
• Coverage rate of total measurement area
• Displaying coverage rate of load module
• Summary of 16 addresses as one block
• Details indicating access status of each address
• Displaying coverage measurement result per source line
• Displaying coverage measurement result per machine instruction
- Display Coverage Rate of Total Measurement Area (Specify /TOTAL for command qualifier.)
>SHOW COVERAGE/TOTAL
total coverage : 82.3%
CHAPTER2 Dependence Functions
: SET COVERAGE
: GO, STEP, CALL
: SHOW COVERAGE