Command – 06 - Hitachi L300P Series Instruction Manual

Three-phase input 200v class; three-phase input 400v class;
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Command – 06
The 06 command reads a single parameter
value from the inverter, which is specified by
the data field this read command.
STX
Node
Command
Data
BCC
[CR]
The receive frame includes an ACK
(acknowledge) character, followed by an
8-byte data field.
STX
Node
ACK
Data
BCC
[CR]
Use the codes in the table below to return parameters for H03 and H203 (motor capacity selec-
tion).
U.S. mode (B85=00, 02) 0.2 kW
EU mode (B85=01)
U.S. mode (B85=00, 02) 5.5 kW
EU mode (B85=01)
Element
Description
Control code (STart of TeXt)
Node (station) address of inverter
Transmission command
Parameter specified to be read
Block check sum code
Control code (carriage return)
Element
Description
Control code (STart of TeXt)
Node (station) address of inverter
Control code (ACKnowledge)
Parameter value
Block check sum code
Control code (carriage return)
Code Data
00
0.2 kW
Code Data
11
5.5 kW
Transmit frame format
STX Node
Command
Size
1 byte
STX (0x02)
2 bytes 01 to 32
2 bytes 06
4 bytes (see tables below)
2 bytes Exclusive OR of Node,
Command, and Data
1 byte
[CR] (0x0D)
Receive frame format
STX Node
ACK
Size
1 byte
STX (0x02)
2 bytes 01 to 32
1 byte
ACK (0x06)
8 bytes Value of parameter times ten,
returned as ASCII char. code,
except for H003 and H203 (see
table below)
2 bytes Exclusive OR of Node,
Command, and Data
1 byte
[CR] (0x0D)
01
02
03
04
05
0.4
0.75
0.37
0.55 0.75
1.1
12
13
14
15
16
7.5
11
15
18.5
22
7.5
11
15
18.5
22
B–13
L300P Inverter
Data
BCC [CR]
Value
Data
BCC [CR]
Value
06
07
08
09
10
1.5
2.,2
3.7
1.5
2.2
3.0
4.0
17
18
19
20
21
30
37
45
55
75
30
37
45
55
75

Advertisement

Table of Contents
loading