Configuring the Inverter for Multiple Motors
Parameters for the second motor have function codes of the form x2xx. They appear immedi-
ately after the first motor's parameter in the menu listing order. The following table lists the
parameters that have the second parameter registers for programming.
Function Name
Multi-speed frequency setting
Acceleration time setting (Acceleration 1)
Deceleration time setting (Deceleration 1)
Second acceleration time setting (Acceleration 2)
Second deceleration time setting (Deceleration 2)
Select method to use 2nd acceleration/deceleration
Acc1 to Acc2 frequency transition point
Dec1 to Dec2 frequency transition point
Level of electronic thermal setting
Select electronic thermal characteristic
Torque boost method selection
Manual torque boost value
Manual torque boost frequency adjustment
V/F characteristic curve selection
Base frequency setting
Maximum frequency setting
Select motor constant
Motor capacity setting
Motor poles setting
Motor stabilization constant
Parameter Codes
1st motor
2nd motor
A020
A220
F002
F202
F003
F203
A092
A292
A093
A293
A094
A294
A095
A295
A096
A296
B012
B212
B013
B213
A041
A241
A042
A242
A043
A243
A044
A244
A003
A203
A004
A204
H002
H202
H003
H203
H004
H204
H006
H206