For example, you can set B037=01 to have the inverter suppress the displaying of all analog
input parameters when A001=01, as shown in the first row of the following table.
Function
Data
Code
A001
01
A002
01, 03, 04,
05
A019
00
C001 – C005 02, 03, 04,
05
A044, A244
02
A051
01
A071
01
A094
01
A294
01
B013, B213
02
B021
01, 02
B024
01, 02
B095
01, 02
06
08
C001 – C005
11
18
27, 28, 29 C101
A094
01
A294
01
A097
01, 02, 03 A131
A098
01, 02, 03 A132
B098
01, 02
C021, C022,
02, 06
C026
Resulting Non-displayed
Functions (when B37 = 01)
A005, A006, A011 – A016,
A101–A105, A111 – A114,
C081 – C083, C121 – C123
B087
A028 – A035
B100 – B113
A052 – A059
A072 – A076, C044
A095 – A096
A0295 – A296
B015 – B020
B022, B023
B025, B026
B090 – B096
A038, A039
A203, A204, A220, A241 –
A244, A261, A262, A292, A293
– A296, B212, B213, H203,
H204, H206
B088
C102
A131
A095, A096
B099, C085
C042, C043
3–37
L300P Inverter
Notes
[O], [OI], [O2] terminal
functions
Stop key function
Multi-speed function
Control methods
DC braking
PID function
2-stage adjustable frequency
Electric thermal characteris-
tic
Overload restriction
Overload restriction 2
Dynamic braking function
Jogging
2nd motor control
Free-run stop
Reset
UP/DWN
Select method to switch to
second accel/decel profile
Select method to switch to
second accel/decel profile,
2nd motor
Acceleration pattern
constant
Deceleration pattern
constant
Thermistor function
Frequency arrival signal