Delay Spin (Ds) Stagger Spin (Ss); Single-Ended Operation _ Force Se )Disable Lvd); Remote Busy And Fault Displays - Maxtor Atlas 10K V Product Manual

Table of Contents

Advertisement

3.4.2.2
Delay Spin (DS), Stagger Spin (SS)
Maxtor Atlas 10K V drives have three Spin Up modes:
Option 1 (No jumpers installed):
Option 2 (Delay Spin jumper installed):
3.4.2.3
Single-Ended Operation – Force SE (Disable LVD)
Install a jumper across pin pair 17/18 (SE) on the J3 Option Header to operate the
disk drive as a single-ended device. Remove the SE jumper for LVD operation and
monitoring of the DIFFSENS signal.
3.4.2.4

Remote Busy and Fault Displays

Busy and Fault status of the drive can be monitored remotely by connecting a
remote (external) Busy and/or remote Fault display LEDs.
Remote Fault LED
On the J1 Option Connector, connect the cathode side of the remote Fault LED
to pin 2, Fault LED. Connect the anode side of the LED to pin 11, +5V.
Spin up immediately when power is applied. Verify that no jumper is installed
across the Delay Spin pin pair of the J3 Option Header.
Spin up on START STOP UNIT command: Install the jumper across pin pair
15/16 (GND/Delay Spin) on the J3 Option Header.
Maxtor Atlas 10K V
3-9