11.11 Aligning the Light Barriers of the Remaining Thread Monitor

1
2
3
The light barrier mountings 3 and 6 are set at the factory so that a
sufficient safety clearance of 5-6 mm to the moving hooks is provided.
The alignment of the reflecting light barriers occurs in program P51.
ATTENTION !
The remaining thread monitor is only activated when the value for the
underthread counter is set to "0000" in program P41.
Calling up the alignment
Set the "Program" switch to "41".
Press the "STOP" key
The program is activated.
The lower line of the display shows two bobbins.
Insert an empty bobbin in the bottom of the bobbin case.
Turn the empty bobbin manually.
If the infra-red beam of the light barrier hits the reflecting surface 7
of the bobbin hub this must be shown in the display.
A reflection of the left light barrier is shown in the left half of the
lower line of the display by the symbol "]->>".
A reflection of the right light barrier is shown in the right half of the
lower line of the display by the symbol "<<-[".
If no reflection is indicated when turning the empty bobbin then the
alignment of the light barrier is to be corrected.
Correcting the alignment
Clean the lenses of the light barriers 1 and 5 and the reflecting
surfaces 7 of the bobbin hubs with a soft cloth.
Loosen clamping screw 2 or 4.
Align light barrier 1 or 5 respectively by a slight movement on the
bracket 3 resp. 6.
The infra-red beam of the light barrier 1 or 5 must strike the bobbin
hub unhindered through the light opening in the bobbin case.
Tighten the clamping screw 2 or 4.
Check the alignment of both light barriers again.
4
5
6
7
59