Light Barrier Of Residual-Thread Monitor - Duerkopp Adler 743-221 Service Manual

Hide thumbs Also See for 743-221:
Table of Contents

Advertisement

2.9

Light barrier of residual-thread monitor

14
1
2
Regulation and inspection
If the light barrier is properly aligned a reflection occurs when an
empty bobbin is rotated.
The alignment of the light barrier is carried out in program 42.
Caution: danger of injury
Turn off the motor safety switch.
The reflex light barrier may only be aligned with the motor safety
switch turned off.
IMPORTANT !
The residual-thread monitor is only operational if the value for the
shuttle-thread counter in program 41 has been set to 0000.
Checking the alignment
Place an empty bobbin on the sleeve (gauge 5, section 2.1) and
insert it in the bobbin housing.
Move the shuttle by turning the handwheel until the infra-red
radiation of the light barrier 1 can fall on the bobbin hub through
the light aperture in the bobbin housing (shuttle beak down).
Set "program" switch to 42.
Press "STOP" button.
The program is activated.
Rotate empty bobbin with the sleeve (gauge 5).
If the infrared radiation from light barrier 1 falls on the reflective
surface 3 of the bobbin hub, this must appear in the display:
display with reflection:
display with no reflection: