2.9 Remaining Thread Monitor

1
The remaining thread monitor monitors the thread reserve on the the
underthread bobbin with the infrared reflecting light barrier 1.
Function
After a certain number of seams the underthread reserve on the
bobbin is used up.
The light beam transmitted from light barrier 1 is reflected by the
exposed reflecting surface 2 on the bobbin hub.
The display of the controls shows the message " Bobbin Empty ".
The seam is securely ended with the thread reserve found in the
reserve groove.
Caution Risk of Injury !
Turn the main switch off.
Change the underthread bobbin only with the sewing unit turned off.
Turn the main switch off.
Change the bobbin.
At every bobbin change clean the lenses of the light barrier with a
soft cloth.
Turn the main switch on.
Start a new sewing sequence.
2
3