3.4 Guide Plates on the Folder

With the needle bar link in the most forward position the edges 2 of the
guide plates must extend approx. 1 mm to the rear beyond the needles.
The leaf springs 1 hold the guide plates down on the folder sole with a
slight pressure.
The pressure must so dimensioned that the sprung guide plates can
be easily raised by the piping strip running in or by the flap.
1
2
1 mm
Caution Risk of Injury !
Turn the main switch off.
Correct the pressure of the leaf springs only with the main switch
turned off.
To correct:
Set the pressure by adjusting the leaf springs 1.