4.2.5.15 Paper Release Solenoid Assembly Removal
When mounting the sensor, the stud should be fixed in the frame hole. Otherwise paper
release mechanism will not function correctly.
Step 1:
Remove the printer mechanism. (Refer to Section 4,2,5,1,)
Step 2:
Remove the paper tension assembly. (Refer to Section 4.2.5.5.)
Step 3:
Remove the paper feed motor, being careful not to lose the spring at the rear of the motor.
(Refer to Section 4.2.5.7.)
Step 4:
Remove the paper feed reduction gear and the platen. (Refer to Section 4.2.5 .10.)
Step 5:
Remove the tractor transmission gear and the paper release lever by pushing the loading
trigger plate in the direction of the arrow.
Step 6:
Remove the two screws CB(M2X8) and CPS(M3X8) securing the paper release solenoid
assembly (one is for sensor and the other is for solenoid), then remove the paper release
solenoid assembly (sensor and solenoid).
Figure 4-47. Paper Release Solenoid Assembly
W A R N I N G
Loading Trigger Plate
Release Lever Removal
Figure 446. Paper
Release Trigger Plate
Paper Releaae
Planetary Lever
\
\
.
\
"Tractor Transmission
\ .
Release Sun Gear
Paper Release Lever
—. /Tractor Transmission Gear
Paper Feed Motor
4 - 2 8
Gear
-

Removal

. :. ,,
.., -,.
- . - '