Error Reporting and Handling
6.3.8
Memory Error Codes
Tpoint
001h
002h
0E1h
0E2h
0E3h
0E4h
0E5h
0E6h
0E8h
0E9h
0EAh
0EBh
0ECh
0EDh
0EEh
0EFh
0F0h
0F1h
0F2h
0F3h
0F4h
®
6.4
Intel
Light-Guided Diagnostics
The server board provides system fault/status LEDs in many areas of the board to alert users to
a particular failure or status of a component on the board. There are fault LEDs for the memory
DIMMs and processors, and status LEDs for 5-volt stand-by and system state.
140
Intel® Server Boards SE7320SP2 and SE7525GP2
Table 70. Memory Error Codes
Description
MEM_ERR_CHANNEL_B_OFF
(DIMM mismatch forced Channel B disabled)
MEM_ERR_CK_PAIR_OFF
(Slow DIMM(s) forced clock pair disabled)
MEM_ERR_NO_DEVICE
(No memory installed)
MEM_ERR_TYPE_MISMATCH
MEM_ERR_UNSUPPORTED_DIMM
(Unsupported DIMM type)
MEM_ERR_CHL_MISMATCH
MEM_ERR_SIZE_MISMATCH
MEM_ERR_ECC_MISMATCH
MEM_ERR_ROW_ADDR_BITS
MEM_ERR_INTERNAL_BANKS
MEM_ERR_TIMING
MEM_ERR_INST_ORDER_ERR
MEM_ERR_NONREG_MIX
MEM_ERR_LATENCY
MEM_ERR_NOT_SUPPORTED
MEM_ERR_CONFIG_NOT_SUPPORTED
SYS_FREQ_ERR
(Flag for Unsupported System Bus Freq)
DIMM_ERR_CFG_MIX
(Usupported DIMM mix)
DQS_FAILURE
(indicates DQS failure)
MEM_ERR_MEM_TEST_FAILURE
(Error code for unsuccessful Memory Test)
MEM_ERR_ECC_INIT_FAILURE
(Error code for unsuccessful ECC and Memory Initialization)
Revision 4.0