3-2-10. X-Y movement

This procedure lets you set the parallel movement of the pattern in the X feed direction
and Y feed direction.
The setting range is from -1 to +1 in both the X direction and Y direction. However, it may
not be possible to change the setting within this range because an area check will be
carried out when the setting is changed.
w
AUTO MODE
Loop length
1st bobbin counter
2nd bobbin counter
ADJUSTMENT(/)
Loop/ program
X-Y/ test feed
X-Y/ feed
X-Y/MOVE/ (ADJ)
Program No.
Xmove (mmx10)
X-Y/MOVE/ (ADJ)
Program No.
Xmove (mmx10)
MODE
SELECT
e
z/
z/
WARNING
CANCEL
ENTER
t
1. Press the MODE switch w to select AUTO mode.
2. While pressing the
MODE switch w.
* This will change the mode to ADJUSTMENT
mode.
SELECT switches e to move the
3. Use the
and
pointer " " so that "X-Y/program" is selected, and
then press the ENTER switch t.
4. Use the
and
move the pointer " " so that "X move" or "Y move"
is selected.
5. While using the
cursor "-" , press the
e to set the amount of movement.
* If the CANCEL switch r is pressed, the
old previously-set scale ratio will appear again
on the display.
6. Press the ENTER switch t.
* The new scale ratio setting for the X move or Y
move will appear on the display.
23