Action at an Alarm Occurrence

The alarm action will be performed when the following alarm occur.
Alarm type
Terminal alarm: When connecting an alarm device such as a sensor to the connector terminal (Alarm Input 1 to
4) on the rear of the unit, the alarm action (unit action at an alarm occurrence) will be performed when the
connected alarm device is activated. Alarm action to be performed differs depending on the settings config-
ured on the [Alarm] tab. ( page 32)
Camera site alarm: When a camera connected to a VIDEO IN connector detects an alarm by alarm sensors or
cameras' motion detectors, etc., and the unit receives the alarm input signal from the camera, the alarm
action will be performed. ( page 32)
Video Loss: When the loss of video input signals is detected due to coaxial cable disconnections or camera
troubles, the alarm action will be performed. ( page 32)
Command alarm: When a Panasonic alarm protocol is received from the connected device via a network, the
alarm action will be performed. ( page 32)
Action at an Alarm Occurrence
Display the [Alarm occurrence indication] button on the "Live" page ( page 5).
The [Alarm occurrence indication] button will be displayed on the "Live" page at an alarm occurrence.
Note:
The [Alarm occurrence indication] button will be refreshed in 30 seconds intervals. For this reason, it may take a
maximum of 30 seconds until the [Alarm occurrence indication] button is displayed on the "Live" page at an alarm
occurrence.
Notify of alarm occurrences to the device connected to the alarm connector
It is possible to output signals from the alarm connector on the rear of the unit and sound the buzzer when an alarm
occurs. The settings for the alarm output can be configured on the [Alarm] tab of the "Alarm setup" page.
( page 32)
Transmit an image onto a server automatically
An alarm image can be transmitted at an alarm occurrence to the server designated in advance. The settings
required to transmit an alarm image to a server can be configured in the "Alarm image setup" section of the [Alarm]
tab of the "Alarm setup" page ( page 33) and the [FTP] tab of the "Server setup" page ( page 40).
Notify of alarm occurrences by e-mail
Alarm mail (alarm occurrence notification) can be sent at an alarm occurrence to the e-mail addresses registered in
advance. Up to 4 addresses can be registered as recipients of the alarm mail. The settings for alarm mail can be
configured in the "E-mail notification setup" section of the [Notification] tab of the "Alarm setup" page ( page 35)
and the [Mail] tab of the "Server setup" page ( page 40).
Notify of alarm occurrences to the designated IP addresses (Panasonic alarm protocol)
This function is available only when Panasonic device, such as the network disk recorder, is connected to the sys-
tem. When "ON" is selected for "Panasonic alarm protocol", the connected Panasonic device will be notified that the
unit is in the alarm state. The settings for Panasonic alarm protocol can be configured on the [Notification] tab of the
"Alarm setup" page. ( page 36)