Rebuilding Drives Manually - HP P3410A - NetRAID 1M RAID Controller User Manual

Hp netraid series user guide
Hide thumbs Also See for P3410A - NetRAID 1M RAID Controller:
Table of Contents

Advertisement

Chapter 5
You can view or change the Rebuild Rate from any of the three HP NetRAID
utilities.
To view or change the Rebuild Rate from HP NetRAID Express Tools:
1. If you have more than one adapter, choose Select Adapter from the Tools
Management menu, and then select the adapter for which you want to
change or view the Rebuild Rate.
2. Choose Objects from the HP NetRAID Express Tools Management menu.
3. Choose Adapter from the Objects menu.
4. Select View/Update Rebuild Rate.
5. Use the arrow keys to increase or decrease the amount of processor time
dedicated to rebuilding the failed disk.
6. If you want to change the Rebuild Rate on another adapter, press Esc to
return to the Tools Management menu. Then repeat Steps 1 through 5 for
that adapter.
7. When you have changed the Rebuild Rate on all adapters, press Esc
repeatedly to back up to the Tools Management menu.
To view or change the Rebuild Rate from HP NetRAID Assistant:
1. If you have more than one adapter, click on the Adapter box and choose
the adapter from the pull-down list.
2. Choose Adapter from the HP NetRAID Assistant Management menu.
3. Choose Rebuild Rate from the Adapter menu.
To view or change the Rebuild Rate from HP NetRAID Config:
1. Choose Adapter from the HP NetRAID Config Management menu.
2. Choose View/Update Parameters from the Adapter menu.

Rebuilding Drives Manually

You must initiate a manual rebuild under any of several conditions:
Autorebuild was disabled.
The hot spare or replacement drive does not have enough capacity to
rebuild the failed drive.
104
Reconstructing and Rebuilding Drives